DISAB Portable Vacuum toppled over at 45 degrees coming to rest against extruder guarding.
Causes
Hazard awareness - The risk of not having unit fixed was not foreseen
Systems - No procedure in place for regular inspection
Equipment - Bolt had come lose securing leg