Incident alert

LOCATION:
QUARRY
ACTIVITY:
OCCUPATIONAL HEALTH
SUB ACTIVITY:
N/A
ALERT STATUS:
Normal
DATE ISSUED:
11/07/2008
INCIDENT No:
00182

TITLE
Identification of a Confined Space
COUNTRY OF ORIGIN
United Kingdom
ACCIDENT / INCIDENT DETAILS
On a routine inspection of this site it became apparent that contractors and Hanson personnel failed to identify a confined space, or eliminate reasonably foreseeable hazards to remove the confined space risk.

Before working in any excavation ensure the following are controlled:
Carbon Monoxide ingress, as it is heavier than air. Ingress of material from drains.
Ensure emergency evacuation procedures are in place.
Ensure RA & SWP are adequate.
Ensure competency.
ACCIDENT / INCIDENT IMAGES
Click image to enlarge

Click image to enlarge

LEARNING POINTS / ACTIONS TAKEN
Remove the JCB to eliminate the possibility of fume flowing into the excavation.
Ensure RA & SWP are suitable, sufficient and relate to the task.
Arrange for HC management to attend Managing Confined Space training